13-網絡管理和監控配置指導

目錄

04-時鍾監控配置

本章節下載 04-時鍾監控配置  (198.75 KB)

04-時鍾監控配置

目 

1 時鍾監控配置································································································································· 1-1

1.1 時鍾監控模塊簡介···················································································································· 1-1

1.1.1 時鍾監控模塊概述·········································································································· 1-1

1.1.2 時鍾源的分類················································································································ 1-1

1.1.3 參考源的級別················································································································ 1-1

1.1.4 時鍾監控模塊的工作模式································································································ 1-2

1.1.5 端口的時鍾工作模式······································································································· 1-2

1.2 時鍾監控模塊配置任務簡介······································································································· 1-3

1.3 配置時鍾監控模塊的工作模式··································································································· 1-3

1.4 設置參考源的優先級················································································································ 1-4

1.5 配置參考源的SSM參數··········································································································· 1-4

1.5.1 設置SSM級別的確定方式······························································································ 1-4

1.5.2 設置傳輸Bits時鍾源SSM級別信息的比特位··································································· 1-5

1.5.3 設置參考源的SSM級別································································································· 1-5

1.5.4 設置SSM是否參與控製································································································· 1-6

1.6 設置線路時鍾源的輸入端口(LPU Port)··················································································· 1-6

1.7 時鍾監控模塊顯示和維護·········································································································· 1-7

1.8 時鍾監控模塊典型配置舉例······································································································· 1-8

 


1 時鍾監控配置

1.1  時鍾監控模塊簡介

1.1.1  時鍾監控模塊概述

時鍾監控模塊負責向各業務接口板提供高精度、高可靠性的同步SDH(Synchronous Digital Hierarchy,同步數字係列)線路接口時鍾信號,完成輸入時鍾源的自動選擇、軟件鎖相功能,並實時監測接口板的時鍾狀態。此外,時鍾監控模塊還支持時鍾扣板的硬件複位。

目前時鍾監控模塊支持14路參考時鍾源(以下簡稱參考源),其中第一路和第二路為Bits時鍾源,分別對應主用主控板的外部時鍾輸入1和輸入2,其它的為線路時鍾源。圖1-1是設備的參考源與槽位的對應關係圖,可以看到S9505E設備上,2號槽位的線路時鍾對應第9路參考源,3號槽位的線路時鍾對應第10路參考源。

圖1-1 參考源與槽位的對應關係

 

1.1.2  時鍾源的分類

根據時鍾源的來源不同,可以將時鍾源分為以下三類:

·     本地時鍾源:由時鍾監控模塊內部晶體震蕩器產生的38.88MHz時鍾信號。

·     Bits時鍾源:由專門的Bits時鍾設備產生,Bits時鍾通過主控板上的專用接口,直接傳送給時鍾監控模塊,時鍾監控模塊再發送給所有接口板。

·     線路時鍾源:由上一級設備提供,精度比Bits時鍾源低。通過指定的WAN接口輸入,係統提取時鍾信號後,傳送給時鍾監控模塊,時鍾監控模塊再發送給所有接口板。

1.1.3  參考源的級別

參考源的級別由參考源的優先級和參考源的SSM(Synchronization Status Marker,同步狀態信息)級別共同確定。

1. 參考源的優先級

用戶可以給高精度、高可靠性的參考源設置較高的優先級,以便在選擇時鍾源時優先被選擇。

2. 參考源的SSM級別

SSM也稱同步質量信息,用於在同步定時傳遞鏈路中直接反映同步定時信號的等級。

參考源的SSM級別及其各自的含義按照級別由高到低的順序排列如下:

·     PRC:G.811時鍾信號

·     TNC:G.812轉接節點時鍾信號

·     LNC:G.812本地節點時鍾信號

·     SETS:SDH設備時鍾源信號

·     unknown:同步質量未知

·     DNU:不應用作同步

說明

SSM級別為DNU的參考源不能用作時鍾源。

 

1.1.4  時鍾監控模塊的工作模式

時鍾監控模塊的工作模式,即時鍾監控模塊選擇時鍾源的模式,包括手動模式和自動模式。

1. 手動模式

手動模式下的時鍾源由用戶手工設置。時鍾監控模塊不主動切換時鍾源,隻跟蹤用戶設置的主用參考源。如果主用參考源丟失,時鍾監控模塊轉入保持狀態。

2. 自動模式

自動模式下的時鍾源由係統自動設置。在當前主用時鍾源丟失或不可用時,時鍾監控模塊會根據參考源級別來主動切換時鍾源。切換時遵循以下規則:

·     如果SSM級別不參與控製,時鍾監控模塊直接按參考源的優先級選擇時鍾源。如果兩個參考源優先級相同,則按照參考源的編號順序(1~14)進行選擇。當可用的最高級別的參考源丟失時,自動切換到下一個可用的最高級別的參考源。當原時鍾源恢複時,自動切換回原時鍾源。

·     如果SSM級別參與控製,則時鍾監控模塊首先按參考源的SSM級別選擇時鍾源,如果兩個參考源的SSM級別相同,再按照參考源的優先級選擇,具體方式請參見上一段中的相關說明。

說明

以下參考源在切換時不會被選擇:

·     信號丟失的參考源為不可用時鍾源,不參與切換;

·     優先級為255的參考源為未配置優先級的時鍾源,不參與切換;

·     SSM級別為DNU的參考源為不可用時鍾源,不參與切換。

 

1.1.5  端口的時鍾工作模式

根據端口時鍾的來源,設備的端口支持兩種時鍾模式:

·     主時鍾模式(Master):使用時鍾監控模塊提供的時鍾信號。這個時鍾信號包括本地時鍾信號以及從LPU Port(時鍾信號輸入端口)提取的時鍾信號。在主時鍾模式下,如果設備上沒有配置從LPU Port提取時鍾信號,就采用本地時鍾信號;如果配置了從LPU Port提取時鍾信號,就采用LPU Port提取的時鍾信號。

·     從時鍾模式(Slave):使用線路提供的時鍾信號。此時必須把設備的LPU Port指定為當前端口,係統才會從當前端口收到的線路信號中提取時鍾源,然後發送給時鍾監控模塊,再由時鍾監控模塊輸出到所有接口板。

提示

當與SONET/SDH設備相連時,由於SONET/SDH網絡的時鍾精度高於設備本身內部時鍾源的精度,應配置設備工作在從時鍾模式。

 

1.2  時鍾監控模塊配置任務簡介

表1-1 時鍾監控模塊配置任務簡介

配置任務

說明

詳細配置

配置時鍾監控模塊的工作模式

可選

1.3 

設置參考源的優先級

可選

1.4 

配置參考源的SSM參數

設置SSM級別的確定方式

可選

1.5.1 

設置傳輸Bits時鍾源SSM級別信息的比特位

可選

1.5.2  

設置參考源的SSM級別

可選

1.5.3 

設置SSM是否參與控製

可選

1.5.4 

設置線路時鍾源的輸入端口(LPU Port)

可選

1.6 

 

1.3  配置時鍾監控模塊的工作模式

表1-2 配置時鍾監控模塊的工作模式

操作

命令

說明

進入係統視圖

system-view

-

設置時鍾監控模塊的工作模式

clock { auto | manual source source-number }

可選

缺省情況下,時鍾監控模塊的工作模式為自動模式

 

說明

設置時鍾監控模塊的工作模式後設備響應需要一定時間,可通過display clock device命令和日誌信息查看配置是否生效。

 

1.4  設置參考源的優先級

在自動模式下,時鍾監控模塊會根據SSM級別及參考源的優先級選擇時鍾源,並主動切換到優先級高的參考源。

表1-3 設置參考源的優先級

操作

命令

說明

進入係統視圖

system-view

-

設置參考源的優先級

clock priority value source source-number

必選

缺省情況下,參考源的優先級為255

 

1.5  配置參考源的SSM參數

1.5.1  設置SSM級別的確定方式

參考源的SSM級別的確定方式有兩種:

·     對於bits時鍾源,SSM級別可以從接口板輸入的時鍾信號中提取,並上報給主控板,主控板將bits時鍾源的SSM級別設置給時鍾監控模塊。

·     用戶自行設置SSM級別,操作步驟請參見表1-6

表1-4 設置SSM級別的確定方式

操作

命令

說明

進入係統視圖

system-view

-

設置SSM級別的確定方式

clock forcessm { on | off } source source-number

可選

缺省情況下,不從時鍾源中提取SSM級別,即使用用戶自行設置的SSM級別

 

1.5.2  設置傳輸Bits時鍾源SSM級別信息的比特位

傳輸Bits時鍾源SSM級別信息的比特可以設置為sa4(sa4比特)、sa5(sa5比特)、sa6(sa6比特)、sa7(sa7比特)和sa8(sa8比特)。按照ITU-TG.704 CRC4規定,sa4sa8表示複幀中偶數幀的0時隙的sa4~sa8共5個比特,可選擇一個比特承載Bits時鍾源的SSM級別信息。

表1-5 設置傳輸Bits時鍾源SSM級別信息的比特位

操作

命令

說明

進入係統視圖

system-view

-

設置傳輸Bits時鍾源SSM級別信息的比特位

clock sa-bit { sa4 | sa5 | sa6 | sa7 | sa8 } source source-number

可選

缺省情況下,傳輸Bits時鍾源SSM級別信息的比特位為sa4

 

1.5.3  設置參考源的SSM級別

用戶可以自行設置時鍾源的SSM級別,但是否生效,還需遵循以下規則:

·     對於線路時鍾源,設置的SSM級別為該時鍾源的SSM級別。

·     對於Bits時鍾源,如果輸入信號為2048kbit/s(E1)信號,或輸入信號為2048kbit/s信號,且執行了命令clock forcessm off source source-number,則時鍾源的SSM級別為從輸入信號中提取的SSM級別,設置的SSM級別被忽略。

·     對於Bits時鍾源,如果輸入信號為2048kHz信號,或輸入信號為2048kbit/s信號,且執行了命令clock forcessm on source source-number,則設置的SSM級別為該時鍾源的SSM級別。

表1-6 設置時鍾源的SSM級別

操作

命令

說明

進入係統視圖

system-view

-

設置參考源的SSM級別

clock ssm { dnu | lnc | prc | sets | tnc | unknown } source source-number

必選

缺省情況下,所有參考源的SSM級別為unknown

 

說明

·     SSM級別為DNU的參考源為不可用時鍾源,當時鍾監控模塊工作在自動方式時,此類參考源不參與切換。

·     設置參考源的SSM級別後設備響應需要一定時間,可通過display clock ssm-level命令和日誌信息查看配置是否生效。

 

1.5.4  設置SSM是否參與控製

不管時鍾源SSM級別是從時鍾信號中提取還是用戶自行設定,要使SSM級別生效,還需要設置SSM是否參與控製。

·     SSM參與控製:自動切換時鍾源時,時鍾源的級別將首先按照時鍾源的SSM級別,再按照時鍾源的優先級確定。

·     SSM不參與控製:用戶可以設置和查看SSM級別,但是在自動切換時鍾源時,時鍾源的SSM級別被忽略,直接照時鍾源的優先級確定。

表1-7 設置SSM是否參與控製

操作

命令

說明

進入係統視圖

system-view

-

設置SSM是否參與控製

clock ssmcontrol { on | off }

可選

缺省情況下,時鍾監控模塊SSM不參與控製

 

1.6  設置線路時鍾源的輸入端口(LPU Port)

表1-8 選擇線路時鍾源的輸入端口

操作

命令

說明

進入係統視圖

system-view

-

選擇線路時鍾源的輸入端口

clock lpuport interface-type interface-number

可選

缺省情況下,時鍾源輸入端口是該接口板上按用戶端口名字典序排列的第一個可設置端口

進入接口視圖

(POS接口)

interface interface-type interface-number

-

設置輸入接口的時鍾模式為Slave模式

clock slave

可選

缺省情況下,接口的時鍾模式為Slave模式

 

說明

對於POS接口板來說,當端口的時鍾工作在Slave模式下時,必須通過clock lpuport命令來設置接口板時鍾源的輸入端口。

 

1.7  時鍾監控模塊顯示和維護

在完成上述配置後,在任意視圖下執行display命令可以顯示配置後主控板時鍾監控模塊的運行情況,通過查看顯示信息驗證配置的效果。

表1-9 時鍾監控模塊顯示和維護

操作

命令

查看時鍾監控模塊的當前配置

display clock config [ | { begin | exclude | include } regular-expression ]

查看時鍾監控模塊的詳細信息

display clock device [ | { begin | exclude | include } regular-expression ]

查看線路板輸入時鍾源的端口

display clock lpuport [ | { begin | exclude | include } regular-expression ]

查看時鍾監控模塊的鎖相狀態

display clock phase-lock-state [ | { begin | exclude | include } regular-expression ]

查看所有參考源的優先級

display clock priority [ | { begin | exclude | include } regular-expression ]

查看時鍾監控模塊的自檢結果

display clock self-test-result [ | { begin | exclude | include } regular-expression ]

查看所有參考源的狀態

display clock source [ | { begin | exclude | include } regular-expression ]

查看所有參考源的SSM級別

display clock ssm-level [ | { begin | exclude | include } regular-expression ]

查看輸出時鍾信號的SSM級別

display clock ssm-output [ | { begin | exclude | include } regular-expression ]

查看時鍾監控模塊的版本信息

display clock version [ | { begin | exclude | include } regular-expression ]

查看主控板時鍾監控模塊的工作模式

display clock work-mode [ | { begin | exclude | include } regular-expression ]

 

1.8  時鍾監控模塊典型配置舉例

說明

缺省情況下,以太網接口、VLAN接口及聚合接口處於DOWN狀態。如果要對這些接口進行配置,請先使用undo shutdown命令使這些接口處於UP狀態。

 

1. 組網需求

·     Device A與Device B通過POS接口相連接,Device A設備的主控板上需要帶時鍾監控模塊。

·     Device A的同步時鍾由主控板上的時鍾監控模塊提供。

·     Device B上的同步時鍾通過提取Device A過來的線路時鍾保持同Device A的SDH線路同步。

2. 組網圖

圖1-2 配置時鍾監控模塊組網圖

 

3. 配置步驟

(1)     配置Device A(主時鍾)

# 設置POS3/1/1接口為主時鍾模式,使用本地時鍾信號。

<DeviceA> system-view

[DeviceA] interface pos 3/1/1

[DeviceA-Pos3/1/1] clock master

(2)     配置Device B(從時鍾)

# 配置Device B的線路時鍾源輸入接口為POS3/1/1。

<DeviceB> system-view

[DeviceB] clock lpuport pos 3/1/1

# 設置接口POS3/1/1的時鍾工作模式為Slave。

[DeviceB] interface pos 3/1/1

[DeviceB-Pos3/1/1] clock slave

[DeviceB-Pos3/1/1] quit

# 使從POS3/1/1提取的時鍾源生效:設置時鍾工作模式為手動模式,以S9508E為例,使用第8路時鍾源為主用時鍾源,即3號槽(線路時鍾源與槽位的對應關係請參見圖1-1)。

[DeviceB] clock manual source 8

通過以上設置,Device B的其他WAN接口板的同步時鍾都是時鍾監控模塊通過3號槽位POS接口板的1號端口線路時鍾提取出來的。這樣保持了整個設備的各業務接口板都有一樣的高精度、高可靠性的同步SDH線路接口時鍾信號。