202406132452
Symptom: When you reboot CPLD from HDM, the operation log mistakenly reports that the security bezel is removed.
Condition: This symptom might occur if you reboot CPLD from HDM.
202408070096
Symptom: An error occurs when you upgrade the RUN package of the V007 version for SCPLD on the R4700 G6 server.
Condition: This symptom might occur if you upgrade the RUN package of the V007 version for SCPLD on the R4700 G6 server.
202405071600
Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.
Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.
202406060535
Symptom: When you install the 2E3.S or 12E3.S backplane to the server, drive slot numbers are displayed incorrectly.
Condition: This symptom might occur if you install the 2E3.S or 12E3.S backplane to the server.
202307281682
Symptom: When you install the 8E1.S backplane to the server, drive slot numbers are displayed incorrectly.
Condition: This symptom might occur if you install the 8E1.S backplane to the server.
202307211183
Symptom: When both the OCP 3.0 riser card and OCP network adapters are installed on the server, packet loss might occur on the shared network port.
Condition: This symptom might occur if both the OCP 3.0 riser card and OCP network adapters are installed on the server.
202306250162
Symptom: If PMIC DIMMs of the TI manufacturer are used, BIOS initialization gets stuck.
Condition: This symptom might occur if the CPLD version is V003 and PMIC DIMMs of the TI manufacturer are used together with PMIC DIMMs of other manufacturers.
202306250486
Symptom: The health LED on the chassis ear flashes red when no HDM alarm is present.
Condition: This symptom might occur if a power supply with specific errors are installed.
202304010586
Symptom: HDM displays N/A for hot swapped OCP network adapters of specific models.
Condition: This symptom might occur if you hot swap OCP network adapters of specific models.