Home Support Resource Center Software Download Servers

R3800 G6 Ultra MCPLD(2025/4/1)

Category-Component Type:

Firmware-CPLD

Version:

V009

OS:

N/A-N/A

    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    The software is used to upgrade main control logic CPLD of the R4900 G6 ultra server

  • Installation steps

    Restrictions and guidelines

    None.

  • Publish Description

    Supported products

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4700 G6

    Restrictions and guidelines

    None.

    Version information

    Version number

    CPLD version: V009

     

     

    NOTE:

    You can access the HDM Web interface of the server to identify the version on the System > System Overview > Others page as shown in the following figure. The figure is for illustration only.

     

    Figure 1 Viewing CPLD version

    圖片 3

    Table 2 Version history

    Version number

    Last version

    Release date

    Version type

    Remarks

    V009

    V008

    2025-03-01

    Release version

    N/A

    V008

    V007

    2024-06-17

    Release version

    N/A

    V007

    V006

    2024-03-07

    Release version

    N/A

    V006

    V005

    2023-12-09

    Release version

    N/A

    V005

    V003

    2023-07-10

    Release version

    N/A

    V003

    First release

    2023-05-10

    N/A

    N/A

     

    Supported languages

    English

    Chinese

    Supported devices

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4700 G6

    Hardware and software compatibility matrix

    CAUTION:

    To avoid an update failure, use the following table to verify the hardware and software compatibility before performing an update.

     

    Table 3 Hardware and software compatibility matrix

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6 Ultra,R4700 G6

    Ultra system board MCPLD version

    V009 or later

    Ultra system board SCPLD version

    V009 or later

    Ultra system board VR version

    V003 or later

    HDM version

    1.79 or later

    BIOS version

    6.10.49 or later

    Image file name and MD5 value

    RS3M2C17SB01009.bin: 95b9327b07ddff33dbc0739866a458df

    RS3M2C17SB02009.bin: dafe4f98b7fc43b9c21e35a2b84eb5fc

     

    (Optional) Version compatibility with ISSU

    N/A

    Update recommendation

    Update to this version is recommended.

    Update restrictions and guidelines

    Make sure the server and the HDM client (such as a PC) can reach each other.

    For a successful bulk update, make sure you can update one server successfully before you update the remaining servers.

    You must update both CPLD1 and CPLD2 to version V009 or later..

    During the update, make sure the network connection is available and do not refresh the webpage.

    Do not refresh the page during the update.

    To avoid CPLD or operating system errors, do not power on or power off the server during the firmware update.

    After the firmware is updated, clear the browser cache before you re-log in to HDM.

  • Problems Solved

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202406132452

    Symptom: When you reboot CPLD from HDM, the operation log mistakenly reports that the security bezel is removed.

    Condition: This symptom might occur if you reboot CPLD from HDM.

    202405071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202403052186

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202311141065

    Symptom: HDM does not generate an alarm when a power outage occurs on the DSD card.

    Condition: This symptom might occur if a power outage occurs on the DSD card.

    202401030222

    Symptom: On the R4700 G6 server, a power supply alarm might occur on the riser card installed to PCIe riser connector 4.

    Condition: This symptom might occur if a riser card is installed to PCIe riser connector 4 on the R4700 G6 server.

    202306250162

    Symptom: If PMIC DIMMs of the TI manufacturer are used, BIOS initialization gets stuck.

    Condition: This symptom might occur if the CPLD version is V003 and PMIC DIMMs of the TI manufacturer are used together with PMIC DIMMs of other manufacturers.

    202306250486

    Symptom: The health LED on the chassis ear flashes red when no HDM alarm is present.

    Condition: This symptom might occur if a power supply with specific errors are installed.

    202304010586

    Symptom: HDM displays N/A for hot swapped OCP network adapters of specific models.

    Condition: This symptom might occur if you hot swap OCP network adapters of specific models.

  • New Functions

  • Version:V009(2025/4/1)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    202411120993

    Symptom: When the P9560 storage controller in OCP form is installed to the onboard OCP2 position, HDM displays that the DSD card is present and a DSD card power failure alarm occurs.

    Condition: This symptom might occur if the P9560 storage controller in OCP form is installed to the onboard OCP2 position.

    202406132452

    Symptom: When you reboot CPLD from HDM, the operation log mistakenly reports that the security bezel is removed.

    Condition: This symptom might occur if you reboot CPLD from HDM.

    202405071600

    Symptom: When the RS46R3X16 riser card is installed, PCIe slots 1 and 3 on the riser card cannot identify PCIe modules.

    Condition: This symptom might occur if a PCIe module is installed in PCIe slot 1 or 3 on the RS46R3X16 riser card.

    202403052186

    Symptom: HDM cannot distinguish MCA error types when MCA errors occur.

    Condition: This symptom might occur when MCA errors occur.

    202311141065

    Symptom: HDM does not generate an alarm when a power outage occurs on the DSD card.

    Condition: This symptom might occur if a power outage occurs on the DSD card.

    202401030222

    Symptom: On the R4700 G6 server, a power supply alarm might occur on the riser card installed to PCIe riser connector 4.

    Condition: This symptom might occur if a riser card is installed to PCIe riser connector 4 on the R4700 G6 server.

    202306250162

    Symptom: If PMIC DIMMs of the TI manufacturer are used, BIOS initialization gets stuck.

    Condition: This symptom might occur if the CPLD version is V003 and PMIC DIMMs of the TI manufacturer are used together with PMIC DIMMs of other manufacturers.

    202306250486

    Symptom: The health LED on the chassis ear flashes red when no HDM alarm is present.

    Condition: This symptom might occur if a power supply with specific errors are installed.

    202304010586

    Symptom: HDM displays N/A for hot swapped OCP network adapters of specific models.

    Condition: This symptom might occur if you hot swap OCP network adapters of specific models.

    New Functions