Print

CR16000-M1A設備部分接口不可用

1小時前 發表

組網及說明

不涉及

告警信息

 

問題描述

現場反饋路由器查看display interface brief發現設備隻有部分接口可用,其他接口不顯示,但是設備外觀上不止顯示的這些接口。

過程分析

解決方法

這個設備有兩個模式,對應部分接口可用

切換命令如下,切換需要重啟。現場根據接口需求靈活修改模式。如果不能滿足需求建議現場聯係市場。

 

[DUT]port-working-mode ?

  hg2-card  Specify the hg2-card mode. In this mode, only six GE ports (1 to 6),

            20 XGE ports (7 to 26), two HE ports (27 and 28), four GE copper

            ports (31 to 34) and the card slot are available

  hg4-xp12  Specify the hg4-xp12 mode. In this mode, only four HGE ports (27 to

            30) and 12 XGE ports (15 to 26) are available

[DUT]display port-working-mode

Current port working mode: hg2-card. Specify the hg2-card mode. In this mode, only six GE ports (1 to 6), 20 XGE ports (7 to 26), two HE ports (27 and 28), four GE copper ports (31 to 34) and the card slot are available

Next    port working mode: hg2-card. Specify the hg2-card mode. In this mode, only six GE ports (1 to 6), 20 XGE ports (7 to 26), two HE ports (27 and 28), four GE copper ports (31 to 34) and the card slot are available