Print

MSR5680電源配置較低引起HMIM卡abnormal故障

告警信息

%Nov 12 15:27:28:199 2024 H3C DEV/2/SUBCARD_FAULT: Subcard state changed to Fault on slot 6 subslot 5, type is unknown.
%Nov 12 15:30:29:799 2024 H3C DEV/2/SUBCARD_FAULT: Subcard state changed to Fault on slot 6 subslot 5, type is unknown.

問題描述

安裝HMIM-8GSW板卡,隻能識別一塊,後插的板卡為abnormol,支持的槽位都測試過,都是這個現象,如下圖所示

已經插有3塊子卡,後插的第四塊不管在哪個槽位插入都是abnormal

過程分析

 

查看官網手冊,在當前X1主控下,上述子卡並無數量限製

仔細查看診斷信息,發現有一個電源fail

  ===============display power-supply verbose=============== 

  Index           Status            Type              Descriptio

  -----------------------------------------------------------

  PWR1          normal          AC          PSR300-12A2

  PWR2          fail                        

  PWR3          absent                         

  PWR4          absent                         

 

System power capacity: 300W

Remaining power for HMIM: 50W

 

從上述回顯可知在300W電源下僅剩50W給HMIM子卡,查詢官網手冊這4塊子卡功率,8+8+22+6為44W,逼近50W,在單電源下會發生可能會發生不穩定現象,後插的子卡無法正常使用

 

解決方法

判斷是電源配置過低,售前給出滿配4個300W電源方案,滿配後問題解決